2152
LIME BASE PLASTER

Formerly Name change (available during the year). Previous product 2752.

Lime plaster like in the old days

Pure lime with puzzolan. Cement-free.

  • For traditional plastering of mainly historical buildings.
  • Contains only pure lime, pozzolanic binder and no cement: Suitable for the professional renovation of historic masonry.
  • Naturally absorbs CO2 from the room air.
  • Diffusion open with anti-fungal properties for a good room climate.
  • Contains pozzolan: reduces efflorescence.
  • Long lasting: Pure lime naturally resists degradation.

Area of application

  • Outdoors: wall + ceiling
  • Indoor: wall + ceiling
  • Suitable for monuments and historical buildings
  • Vapour permeable

Processing method

  • For hand and machine processing
  • Pure lime plaster for historic buildings.
  • For interior and exterior use.
  • For stone, brick, mixed and other substrates.
  • Suitable for healthy living (reduces CO2 content when is setting)
  • For vapour permeable masonry.
Kontakty

Processing details

Learn more about technical details for processing this product.

Substrate requirement

The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding substances and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate must be stable in volume.

Substrate preparation

Depending on the absorbency of the substrate and the climatic conditions, it needs to be moistened. Spray the substrate with lime pre-sprinkler Cemix. If necessary, treat non-standard substrates with a suitable method to achieve the desired properties. The substrate must comply with applicable regulations, standards or material manufacturer's recommendations.

Preparation of the mixture

Prepare the material by pouring the dry mixture into the prescribed amount of water and mixing it. Use potable water or water complying with EN 1008 to mix the mixture. Mix using a slow speed propeller mixer. Mix to a homogeneous, lump-free mixture and leave to rest. Then mix again briefly. Use suitable machinery when processing by machine with the prescribed amount of water.

Water demand

CEMIX_blue_handling_water-quantity_25kg_5,25-6,25l
Quantity Liters (Min) Liters (Max)
1 kg 0,21 l 0,25 l
25 kg 5,25 l 6,25 l

Mixing

CEMIX_blue_handling_swirl_5min800x CEMIX_blue_handling_rest_3min
Mixing time
5 min
Mixing speed in Rpm
800x/min
Ripe time
3 min

Processing instructions

Apply the plaster to the surface. Then roughly level the surface with a straight edge or trowel to the desired flatness. After the plaster has set, use a trowel to level the surface to the desired flatness. The minimum setting time for core plaster is considered to be 2 days per 1 mm of applied layer. The plaster forms a base and leveling layer for finish plaster with a surface coating.
At the beginning of setting and hardening, protect the plaster from rapid drying due to sunlight, heat, wind, or low relative humidity. Plastered surfaces should be moistened with a sprayer or covered with damp geotextile as needed. Also protect the plaster from direct water or rain. The condition of the surface must be checked daily. The curing time is up to 14 days. Plaster must not be applied in winter or when night frosts are expected. See WTA guideline 2-7-01/D Lime Plasters in Historic Preservation. The plaster must not be left untreated in the exterior for long periods (especially over the winter period).

Application thickness

CEMIX_blue_techdata_20_10mm
Minimum layer thickness 10 mm
Recommended layer thickness 15 mm
Maximum layer thickness 20 mm

Consumption

CEMIX_blue_techdata_trowel_1,2kg-1mm
Material consumption min.
1.2
Material consumption max.
-
Material consumption in measuring unit
kg/m²/mm

Consumption renders

CEMIX_blue_techdata_trowel_1,2kg-1mm
Use Case Min/Recommend/Max layer thickness Applied thickness Min. consumption in kg/m²/mm Packaging size Yield
en_CZ Base render 10mm-20mm 15 mm 1.2 kg/m²/mm 25 kg 1.389 m²

Working time (potlife)

CEMIX_blue_handling_trowel_120min

120 min

Treatment after application

Non-absorbent materials prolong the maturation period.
After application, the direct negative effects of sun, heat, humidity and draughts should be avoided. Protect from frost and rain. Direct heating of the surface is prohibited.

Tool and cleaning instructions

Wash off tools with water immediately after finishing work. Clean dried residues mechanically.

Technical parameters

Main binder Lime hydrate
Made of material Aggregate, pozzolanic binder, lime hydrate and additives improving the processing and utility properties of the plaster.
Flammability class A1
Max. grain size 1,2mm
Adhesion after dry storage in ≥N/mm²(ETAG004) 0.1
Thermal conductivity λ in W/(m.K) 0.39
Water vapour diffusion resistance factor µ 15
Dry bulk density in Kg/m³ 1200
Dry bulk density in Kg/m³ to 1400

Download

Technical datasheet

Contact: Can we help you?

Ask us your question. Write to us whenever you want. We will reply within 48 working hours.

Telephone 800 022 848

Contact us on the toll-free Customer hotline

  • Opening hours: weekdays 7:30 a.m.–3:00 p.m.
  • Email: info@cemix.cz
     

Contact form

In order to submit the form, please provide your consent to load the reCAPTCHA service first.